Harshaw TLD™ Model 3500 Manual Reader

It is widely used in radiation protection, radiation quality control, identification and detection of irradiated food, industrial radiation control and archaeological geology, especially for scientific research and small and medium-sized dose measurement. The system includes a sample drawer, and only one sample can be measured at a time; A linear program-controlled heating system and an optical measuring unit are used to measure the thermoluminescence information. The PMT of the optical measurement unit is equipped with a thermoelectric cooler, which can ensure the long-term stability of the PMT sensitivity;

Share

Related Products

 
 

It is widely used in radiation protection, radiation quality control, identification and detection of irradiated food, industrial radiation control and archaeological geology, especially for scientific research and small and medium-sized dose measurement. The system includes a sample drawer, and only one sample can be measured at a time; A linear program-controlled heating system and an optical measuring unit are used to measure the thermoluminescence information. The PMT of the optical measurement unit is equipped with a thermoelectric cooler, which can ensure the long-term stability of the PMT sensitivity;

  • The temperature measuring thermocouple is welded at the bottom of the heating metal plate, and the heating repeatability is good, and the maximum heating temperature can be 600 ℃;
  • Select the appropriate sample tray according to the shape and size of the selected detection element
  • Optional neutral density filter to expand high range
  • Dose algorithm meets doelap and nvlap certification requirements
  • Software operation, storing all operation data and operation data
  • Ensure instrument quality through daily inspection and online monitoring
  • It can print various forms of reports directly
  • Comply with en61000, iec61066, nasi and other standards

Radiation protection:

  • Personal dose measurement of external exposure of radiation workers;

     

  • Environmental cumulative dose measurement;

Radiotherapy quality control: verification of radiotherapy plan;

Identification and detection of irradiated food: used to identify whether food has been irradiated;

Archaeological and geological ceramic dating and geological dating;

Industrial irradiation control is used for dose control during X-ray inspection of semiconductor products.

Measuring instrument:

  • Reading speed: install 1 dose element at a time
  • Stability of reference light source: under certain temperature, the deviation of 10 consecutive readings is less than 0.5%
  • Repeatability of temperature rise curve: ± 1 ℃
  • Linearity: deviation less than 1%
  • Stability: read 10 times continuously with standard deviation less than 0 µ Gy (tld700)
  • Dark current: relatively less than 50 μ Gy( 137Cs,TLD700)
  • High voltage stability: ± 0.005% / h; 0.02% / 8 hours
  • Maximum heating temperature: 400 ℃ (common thermocouple); 600 ℃ (special thermocouple)
  • The measuring temperature tm-400 ℃ is adjustable; The measurement time is adjustable from 0 to 999 seconds;

Dosimetric performance index TLD-100 LIF (Mg, Ti):

  • Ray measurement: photon: more than 5kev

Neutrons: thermal neutrons to 100MeV

β: Greater than 70kev

  • Dose range: seven orders of magnitude

Linearity 10 μ Gy - 1Gy

Superlinear 1Gy - 20GY

  • Lower limit of measurement: 10 μ Gy

     

  • Tissue equivalence: almost tissue equivalence

     

  • Uniformity of the same batch: ± 30% (without ECC correction)

     

  • Decay: no heat treatment or use correction, less than 20% / 3 months

Use correction factor or preheating, less than 5% / 3 months

  • Repeatability: 1mgy of 137Cs was used for 10 consecutive times, and the deviation of measurement results was less than 2%.

     

  • Residual signal: less than 2% if not annealed after measurement

Management software:

 

 

  • Multiple user workstations can be established
  • Each user workstation does not interfere with each other and has different data storage addresses
  • Users of each workstation can set multiple different TTP files as required
  • When reading the dose element, you can directly call the TTP file
  • The parameter settings are password protected. If you do not enter the correct user name and password, you can only browse, not change.
  • Select and use correction factors according to actual needs
  • You can enter the background and quality factor to be deducted
  • Dose elements can be classified and managed by group
  • The user can divide four regions of interest according to needs, and the instrument will calculate the dose according to the regions divided by the user
  • Instrument status detection frequency adjustable
  • Testing instrument
  • Automatic storage of instrument operation data and operation data
  • Selectable data storage location
  • Records can be searched by date, dose element number, group number, etc
  • The operation data is displayed in two forms of luminous curve and dose data
  • You can print reports directly
  • You can set the format and output the record