High Purity Germanium Gamma Spectrometer

HPGe  γ The energy spectrometer is used for: γ Nuclide analysis, including U-238, Th-232, Ra-226, K-40, Cs-137, I-131, Co-60 and other nuclide in soil, water, biology, food, aerosol and other samples, is widely used in environmental protection, nuclear power station, nuclear industry, health, customs, food and drug administration, quality supervision and inspection and other units.

Canberra offers many types of detectors. Applying suitable technologies in materials and manufacturing processes, Canberra provides the best detectors for a wide range of applications. P-type germanium and n-type germanium are used, and diffusion, ion implantation, barrier contact and other processes are used to achieve the design and manufacture of various detectors.

Share

Related Products

 
 

HPGe  γ The energy spectrometer is used for: γ Nuclide analysis, including U-238, Th-232, Ra-226, K-40, Cs-137, I-131, Co-60 and other nuclide in soil, water, biology, food, aerosol and other samples, is widely used in environmental protection, nuclear power station, nuclear industry, health, customs, food and drug administration, quality supervision and inspection and other units.

Canberra offers many types of detectors. Applying suitable technologies in materials and manufacturing processes, Canberra provides the best detectors for a wide range of applications. P-type germanium and n-type germanium are used, and diffusion, ion implantation, barrier contact and other processes are used to achieve the design and manufacture of various detectors.

HPGe γ Spectrometer composition:

(1) Hardware: high purity germanium detector + multi-channel analyzer + cryostat + lead chamber;

(2) Software: spectrum acquisition software + spectrum analysis software + passive efficiency calibration software

  • A variety of detectors are available, including p-type coaxial, n-type coaxial, wide energy type, well type germanium detector, etc. the crystal structure and applicable energy range are different
  • Multiple refrigeration modes: liquid nitrogen refrigeration or electric refrigeration
  • HPGe provides superior peak resolution performance compared to all other detector technologies

GB / T 7167-2008 germanium γ Test methods for radiation detectors

GB / T 11713-2015 high purity germanium γ General method for energy spectrum analysis

GB / T 11743-2013 determination of radionuclides in soil γ Energy spectrum analysis method

GB / T 16140-2018 determination of radionuclides in water γ Energy spectrum analysis method

GB / T 16145-2020 determination of radionuclides in biological samples γ Energy spectrum analysis method

HJ 1127-2020 environmental samples in emergency monitoring γ  Technical specification for nuclide measurement

HJ 1129-2020 in situ high purity germanium spectrometer for measuring soil γ  Nuclide technical specification

HJ 1149-2020 ambient air aerosol γ Determination of radionuclides - filter press_ γ Energy spectrum method

Detector Type

BEGe: Broad Energy Germanium Detector

The unique capabilities of Canberra's broad energy region (BEGe) germanium detectors covering the energy range from 3keV to 3MeV. Its resolution in the low-energy region is equivalent to a low-energy germanium detector, and its resolution in the high-energy region is equivalent to a high-quality coaxial detector.

 

Model

Area (cm2)

Length (mm)

Efficiency (≥)

能量分辨力(eV-FWHM)

End window diameter (mm)

 

 

 

 

@5.9keV

@122keV

@1332keV

 

BE5030

50

30

48%

450

750

2100

89

BE6530

65

30

60%

500

750

2200

102

 

 

Standard coaxial germanium detector (Sege)

Canberra's coaxial germanium detectors can be transported and stored at room temperature. The detector is kept cool to best maintain long-term stability. Like all germanium detectors, it must be cooled during use to avoid overheating and leakage current. It is suitable for spectral applications with energies above 40 keV to 10 MeV.

Model

Relative efficiency (≥)

Energy resolution (keV)

Fengkangbi

FWTM/FWHM

End window diameter (mm)

@122keV

@1332keV

GC4018

40%

0.9

1.8

62

1.90

76

GC4020

40%

1.1

2.0

54

2.00

76

GC10023

100%

1.3

2.3

74

2.00

95

 

Reverse polarity coaxial germanium detector (Rege)

The reverse polarity detector (Rege) is geometrically similar to other coaxial germanium detectors, with only one important difference: the electrode of the reverse polarity detector is opposite to the common coaxial detector, that is, the p-type electrode (ion implanted boron) is outside, and the n-type contact (diffused lithium) is inside. This arrangement of electrodes has two advantages: window thickness and resistance to radiation damage. It is suitable for spectral applications with energies from 3kev to 10MeV.

Model

Relative efficiency (≥)

Energy resolution (keV)

Fengkangbi

FWTM/FWHM

End window diameter (mm)

@122keV

@1332keV

GR4522

45

1.1

2.2

54

2.00

83

GR5021

50

1.1

2.2

58

1.90

83

GR10026

100

1.5

2.6

56

2.10

95

 

Detector type

Germanium well detector

The Canberra germanium well detector provides maximum efficiency when counting small samples because the samples are actually surrounded by active detector material. The Canberra germanium well detector is made into a blind hole, leaving at least 5mm of active detector material at the bottom of the well. Therefore, the geometry of the count is approximately 4 π.

Model

Area (cm2)

Well diameter (mm)

Effective volume (CC)

Energy resolution (keV)

@122keV

@1332keV

GCW4022

40

10

190

1.2

2.2

GCW4023

40

16

200

1.4

2.3

 

Extended range germanium detector (xtra GE)

Canberra's extended range germanium detector is a coaxial germanium detector with a unique thin window contact on the front surface, which extends the useful energy range down to 3kev.

Model

Relative efficiency (≥)

Energy resolution (keV)

Fengkangbi

End window diameter (mm)

@22keV

@88keV

@1332keV

GX4020

40

1.0

1.1

2.0

54

76

GX4518

45

0.9

1.0

1.8

63

83

GX8023

100

1.3

1.4

2.3

70

95

 

Low energy germanium detector(LEGe)

Low energy germanium detector (lege) is produced by using thin front contact, and the rear contact is smaller than the full area, so the detector capacitance is smaller than that of planar equipment of similar size, and its noise is lower, so the resolution is better in the low and medium energy range. It is suitable for spectral applications with energy above 3kev.

Model

Area(cm2

Thickness (mm)

Be window thickness(mm)

Energy resolution (keV)

Front amplifier type

@5.9keV

@122keV

GL0055PS

50

5

0.05

145

500

PO

GL0110R

100

10

0.075

180

500

RC

GL3825R

2800

25

0.5

475

750

RC

 

Multichannel analyzer

Dsa-lxtm digital multi-channel analyzer

  • Integrated MCA based on digital signal processing technology (DSP)
  • Excellent counting rate and temperature stability
  • It supports a wide range of time processing and allows accurate
  • matching with detector characteristics and application requirements
  • Equipped with 16K channel conversion gain / spectrum storage
  • Humanized small configuration desktop packaging
  • Provide the function of performing pulse height analysis (PHA) ormulti-channel calibration (MCS)
  • Support advanced patented automatic pole / zero, bottom line recovery and digital spectrum stabilization functions
  • With built-in self diagnosis function after power up

 

Lynxtm digital multichannel analyzer

  • Two sets of 32K channel conversion gain / spectrum memory
    Run in pulse height analysis (PHA), multichannel scaling (MCS), dual channel lossless counting (LFC), multispectral scaling (MSS), and timestamp list mode
  • Excellent count rate and temperature stability
  • Flexible processing time parameter range, which can accurately match application requirements
  • Three HVPS ranges support detectors with low, medium, or high bias requirements
  • Advanced automatic pole / zero US patent # 7725281, baseline recovery and digital stability

 

Inspecortm 2000 digital multichannel analyzer

 

Inspector 2000 instrument is a high-performance portable spectral

  • workstation based on digital signal processing (DSP) technology.
    Unparalleled temperature stability for consistent, high-quality operation under adverse environmental conditions
  • Adapt to the counting rate of wide dynamic range and minimize the loss of spectral resolution
  • Multiple processing time settings can accurately match the detector characteristics and application requirements
  • 16K channel conversion gain / spectrum memory
  • Low system dead time to reduce counting time and improve measurement accuracy

 

Low temperature thermostat series

Traditional liquid nitrogen refrigeration system

 

  • 30L liquid nitrogen tank
  • Or 50L liquid nitrogen tank
  • 30L requires liquid nitrogen to be added once in about 7 days
  • Frequent operation and waste of manpower
  • Low cost

 

Cryo cycle II liquid nitrogen refrigeration system

 

Cryo cycle II liquid nitrogen condensation refrigeration system is a "hybrid" cryostat, because it combines the advantages of electric cooling and the reliability of liquid nitrogen. With cryo cycle II cryostat, LN2 power supply can keep the detector at low temperature for up to one week in case of power failure.

  • LN2 redundancy

     

  • Non CFC / non combustible refrigerant

     

  • Low power demand

     

  • Life of long life pulse tube cooler (L5) > 75000 hours continuous operation

     

  • Low vibration / low electrical noise

 

Cryo pulse 5 electric refrigeration cryostat

 

Cryo pulse 5 electric refrigeration cryostat is an electric cryostat used for HPGe radiation detectors. It is a mature and reliable technology using pulse tube cooler, which is widely used in military and space fields.

  • Using inert gas as refrigerant, there is no pollution and equipment blockage

     

  • MTTF > 3000000 hours

     

  • No maintenance, long service life, mean time between failures greater than 5

    years

     

     

  • Low power demand

     

  • Low vibration / low noise

     

  • Remote read

     

  • Vascular Technology

 

Low background lead chamber

 

  • Top door design, pressure bar type door opening mode

     

  • Integrated pouring lead chamber

     

  • Outer 5mm thick mild steel

     

  • Middle layer: 10cm thick, low background lead

     

  • The lining is 1mm thick tin and 6mm thick copper

     

  • Monolithic casting

 

 

Software System

Genie 2000 leading spectrum measurement and analysis software

Characteristic:

  • When used with Genie 2000 basic spectroscopy software, it provides complete gamma spectrum analysis function
  • Provide interactive spectrum analysis function
  • Support efficiency correction function
  • Provide library related NID peak finding function with background compensation
  • Support interference correction and weighted average activity calculation
  • Provide patented true coincidence (cascade) summation correction function
  • Contains 3D geometric condition editor, which supports interactive definition and visualization of sample, detector and absorber parameters
 

 

ISOCS / Lab SOCS: passive efficiency calibration software

  • Accurate efficiency calibration in the laboratory without radiation source
  • New function: calibration range from 10 keV to 7000 keV
  • What's new: 3D visualization accelerates geometry creation and error recognition
  • New function: true passive cascade summation correction - no source based P / T calibration
  • New function: total efficiency algorithm including cumulative correction
  • New features: beaker Wizard makes building custom beakers faster and easierAccurate calibration at any angle to the detector, not just on the centerline
  • New features: uncertainty estimator and assay planning tool